XTEMOS IS A CREATIVE DESIGN AGENCY

Step 1

Put on hand gloves & PPE

Step 2

Put on one wet wipe at a time

Step 3

Wipe the surface in S-Shaped pattern going from clean to dirty area

Step 4

If the wipe becomes soiled or dry, use a fresh wipe

Step 5

Discard used wies carefullyin waste bins. Do not flush wipes in the toilet

Step 6

Allow the surface to dry before use.

Step 1

Put on hand gloves & PPE

Step 2

If the Surface is havily soiled, Clean it before using the disinfectanat spray

Step 3

Spray 6-8 inches from surface until surface is wet.

Step 4

Allow the surface to dry before use.

Step 1

Put on hand gloves & PPE.

Step 2

Dilute the concentrate as per recommended dilution ratio.

Step 3

Fill the diluted liquid in a bottle or spray pump.

Step 4

If the surface is heavily soild, clean it before using the disinfectant spray.

Step 5

Spray 6-7 inches from surface until surface is wet.

Step 6

Allow the surface to dry before use.

Suface(s) to be Disinfected Suggested Dilution Ratio
HYPEROX QUATTRO QUATTRO Pro5
Floor, Walls, Doorknobs, Push plates, Staircase railing, Surfaces in General Areas 1 : 100
10ml liquid in 1 Lit Water
1 : 100
10ml liquid in 1 Lit Water
1 : 200
5ml liquid in 1 Lit Water
Desk, Table, Chair, Household Appliances, Equipment, Outer Surface of Packaged Goods 1 : 100
10ml liquid in 1 Lit Water
1 : 100
10ml liquid in 1 Lit Water
1 : 200
5ml liquid in 1 Lit Water
Industrial Machinery, Equipment, Storage Area 1 : 100
10ml liquid in 1 Lit Water
1 : 100
10ml liquid in 1 Lit Water
1 : 200
5ml liquid in 1 Lit Water
Personal Effects - Bags, Wallets, Pens, Mobile Phones, Laptops, Keyboard, Mouse 1 : 50
20ml liquid in 1 Lit Water
1 : 50
20ml liquid in 1 Lit Water
1 : 100
10ml liquid in 1 Lit Water
Aerial Fumigation (Fogging), Disinfectant Tunnel 1 : 50
20ml liquid in 1 Lit Water
1 : 50
20ml liquid in 1 Lit Water
1 : 100
10ml liquid in 1 Lit Water
Examination Table, Patient Chair Units, Patient Beds 1 : 20
50ml liquid in 1 Lit Water
1 : 20
50ml liquid in 1 Lit Water
1 : 50
20ml liquid in 1 Lit Water
Diagnostic Equipment, Scanners, MRI Machines, Stethoscope 1 : 20
50ml liquid in 1 Lit Water
1 : 20
50ml liquid in 1 Lit Water
1 : 50
20ml liquid in 1 Lit Water
Slit Lamp, Auto Refractometrs, Perimeter, Lens Trial Sets 1 : 20
50ml liquid in 1 Lit Water
1 : 20
50ml liquid in 1 Lit Water
1 : 50
20ml liquid in 1 Lit Water
Ultrasound Probes, Stethoscopes, Ophthal-moscope, Hand-held devices, OT Furniture -- -- 1 : 20
50ml liquid in 1 Lit Water
Surgical instrument, Rotary Medical Tools, Dental Handpieces, Impression Trays -- -- 1 : 20
50ml liquid in 1 Lit Water
SURFACE COMPATIBILITY
Can be used on
Stainless Steel ABS
Glass Polypropylene (PP)
Chrome Plating PMMA
Glazed Ceramic PVC
Porcelain HDPE
Fabric Granite

SURFACE COMPATIBILITY
Not to be used on
Aluminum Polypropylene (PU)
Brass Vinyl
Galvanized Steel Natural Marble